INDUSTRIAL CHILLER SERIES |
|
water-cooled packaged chiller |
|
- rotary or
scroll hermetic compressor,
to serve the needs of the equipment or
technics
cooling
each industry.
- packaged configuration,has ice water
pump and stainless steel water tank inside.
- microcomputer or plc control.
- temperature control range:3℃-30℃;
- refrigeration capacity:5200Kcal/h -
283500 Kcal/h (3HP-100HP). |
|
|
modle |
WP-03 |
WP-04 |
WP-05 |
WP-06 |
WP-08 |
WP-10
|
WP-12 |
WP-15 |
capacity |
Kcal/h |
5200 |
7900 |
11000 |
14000 |
22800 |
28500 |
32500 |
38000 |
KW |
6.0 |
9.2 |
12.8 |
16.3 |
26.5 |
33.1 |
37.8 |
44.2 |
USRT |
1.7 |
2.6 |
3.6 |
4.6 |
7.5 |
9.4 |
10.7 |
12.6 |
can control temp °C |
3℃-30℃ |
power source |
1PH-220V-50HZ
3PH-380V-50HZ(or 60HZ) |
compressor |
teyp |
rotary hermentic
/ rscroll
hermentic |
powerkw/
HP |
|
2.25/3 |
3/4 |
3.75/5 |
6/8 |
7.5/10 |
9/12 |
11.25/15 |
rated current
A |
8.6 |
12.8/4.6 |
7 |
8.6 |
14 |
17.2 |
21 |
25.8 |
energy control
% |
0,100 |
0,50,100 |
0,33,66,100 |
ice water pump |
power
kw |
0.37 |
0.37 |
0.37 |
0.37 |
0.37 |
0.75 |
0.75 |
1.5 |
flow
l/min |
20-60 |
30-60 |
40-100 |
50-100 |
80-120 |
100-160 |
120-160 |
150-250 |
|
Can be configured as
required (such as material, flow
rate, head, size, etc.) |
evaporator |
type |
Tank type(or
select double-pipe or shell and tube
type or plate type heat exchanger) |
Tank volume L
|
34 |
37 |
37 |
56 |
96 |
102 |
102 |
167 |
pipe dia inch |
1 |
1 |
1 |
1 |
1-1/2 |
1-1/2 |
1-1/2 |
2 |
condenser |
type |
double-pipe type(or
select shell and tube type or plate
type heat exchanger) |
flow
L/min |
40 |
48 |
55 |
70 |
100 |
118 |
135 |
170 |
pipe dia
inch |
1 |
1 |
1 |
1 |
1-1/2 |
1-1/2 |
1-1/2 |
2 |
refrigerant |
type |
R-22 (or select
R407c/R134a/R410A/R404A) |
circuits |
1 |
1 |
1 |
1 |
2(1) |
2(1) |
3(1,2) |
3(1) |
control |
captllary tube
/expansion valve |
protection device |
anti-phase &
lack-phase protector,time delay,the
protection of water shortage,the
control and display of high and low
pressure,the control and display of
temperature,the protectionof over
load,the oil heating,anti-icy
protector,the errors display and so
on. |
Weights kg |
100 |
120 |
130 |
150 |
|
280 |
310 |
490 |
reference dimensions |
H
mm |
820 |
955 |
890 |
970 |
1230 |
1230 |
1270 |
1305 |
W
mm |
435 |
490 |
530 |
530 |
570 |
570 |
650 |
645 |
D
mm |
795 |
810 |
810 |
810 |
1200 |
1200 |
1385 |
1505 |
|
|
|
|
|
|
model |
WP-20 |
WP-25 |
WP-30 |
WP-40 |
WP-50 |
WP-60 |
WP-80 |
WP-100 |
capacity |
Kcal/h |
55000 |
65600 |
75000 |
103000 |
136200 |
162700 |
221000 |
283500 |
KW |
64.0 |
76.3 |
87.2 |
119.8 |
158.4 |
189.2 |
|
|
USRT |
18.2 |
21.7 |
24.8 |
34.1 |
45.0 |
53.8 |
73.1 |
93.8 |
can control temp °C |
3℃-30℃ |
power source |
3φ-380V-50HZ(or select
60HZ) |
compressor |
type |
Scroll hermentic /
reciprocating hermentic |
power kw
/ HP |
|
18.7/25 |
22.5/30 |
30/40 |
37.5/50 |
45/60 |
60/80 |
75/100 |
rated current
A |
30 |
34 |
37 |
48 |
65 |
83 |
103 |
130 |
energy control
% |
|
0,50,100 |
33,66,100 |
0,25,50,75,100
(0,20,40,60,80,100) |
ice water pump |
power
kw |
1.5 |
2.25 |
2.25 |
3.75 |
3.75 |
3.75 |
5.63 |
7.5 |
flow L/min |
250 |
350 |
350 |
560 |
560 |
571 |
747 |
933 |
|
Can be configured as
required (such as material, flow rate,
head, size, etc.) |
evaporator |
type |
Tank type(or
select double-pipe or shell and tube
type or plate type heat exchanger) |
Tank volume L |
240 |
240 |
471 |
600 |
600 |
700 |
800 |
800 |
pipe dia
inch |
2 |
2-1/2 |
2-1/2 |
3 |
3 |
3 |
4 |
4 |
condenser |
type |
double-pipe type(or
select shell and tube type or plate type
heat exchanger) |
flow
L/min |
250 |
300 |
350 |
450 |
550 |
698 |
827 |
1148 |
pipe dia inch |
2 |
2-1/2 |
2-1/2 |
3 |
3 |
3 |
4 |
4 |
refrigerant |
type |
R-22 (or select
R407c/R134a/R410A/R404A) |
circuits |
2(4) |
2(5) |
3(2) |
4(5) |
4(5) |
4(5) |
4(5) |
4(5) |
control |
captllary tube
/expansion valve |
protection device |
anti-phase & lack-phase
protector,time delay,the protection of
water shortage,the control and display
of high and low pressure,the control and
display of temperature,the protectionof
over load,the oil heating,anti-icy
protector,the errors display and so on. |
Weights kg |
660 |
690 |
860 |
1200 |
1450 |
1200 |
1850 |
2100 |
reference dimensions |
H
mm |
1520 |
1520 |
1450 |
1560 |
1560 |
1650 |
1750 |
1750 |
W
mm |
1060 |
1060 |
1100 |
1100 |
1250 |
2650 |
2650 |
3000 |
D
mm |
1200 |
1200 |
1580 |
2050 |
2100 |
950 |
950 |
1100 |
|
|
|
|
|
THE COOLING
IS BASED ON THE FOLLOWING CONDTIONS:
1. CHILLED
WATER INLET OUTLET TEMPERATURE:12/7℃
2. COOLING
WATER INLET OUTLET TEMPERATURE:30/35℃
WORKING
RANGE:
1. CHILLED
WATER OUTLET TEMPERATURE:3-30℃
2. COOLING
WATER OUTLET TEMPERATURE:22-39℃
4OTHER
SPECIFICATION(LOW TEMPERATURE OR SPECIAL
NEEDS)AVAILABLE.
4CHOOSE
DIFFERENT REFRIGERANT,THE COOLING CAPACITY WILL
DIFFERENCES.
4RESERVES THE
RIGHT TO MODIFY THE DETAILS SHOWN HERE IN
WITHOUT PRIOR NOTIFICATION. |
|
|
|