swimming
pool heat pump & dehumidifier & air conditioner |
|
|
|
|
|
|
|
|
|
|
|
SWIMMING POOL HEAT PUMP& DEHUMIDIFIER(RC-A
SERIES) |
FUNCTION: INDOOR AIR DEHUMIDIFY- AIR RECOVERY
HEATING |
|
MODEL |
RC-
1150A |
RC-
1500A |
RC-
2200A |
RC-
3750A |
RC-
6000A |
RC-
7500A |
RC-
11500A |
RC-
15000A |
RC-
22000A |
RC-
30000A |
RC-
37500A |
RC-
45000A |
RC-
60000A |
max air flow m3/h |
1200 |
1500 |
2000 |
3000 |
4500 |
6000 |
9000 |
11000 |
16000 |
22500 |
27500 |
32000 |
45000 |
dehumidify capacity L/h |
4 |
6 |
8 |
13 |
20 |
25 |
40 |
50 |
75 |
100 |
125 |
150 |
200 |
heat pump to air max heating capacityKW |
5 |
7 |
10.6 |
17.7 |
28 |
35.5 |
53.2 |
71 |
106.5 |
142 |
177.5 |
213 |
284 |
refrigerant |
R-22(or
select R407c/R410A/R404A) |
around temperature |
5 - 40°C |
power
source |
1Ø 220V 50HZ |
3Ø 380V 50HZ(or
select 60HZ) |
compressor total power Kw |
1.12 |
1.5 |
2.25 |
3.75 |
6 |
7.5 |
11.2 |
15 |
22.5 |
30 |
37.5 |
45 |
60 |
air fan |
amount |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
excess pressurePa |
≥20 |
≥20 |
≥30 |
≥30 |
≥250 |
≥250 |
≥350 |
≥350 |
≥450 |
≥450 |
≥450 |
≥450 |
≥450 |
air outlet |
free-blow (or select duct-connection) |
duct-connection type |
蒸发器
evaporator |
copper tube&
aluminum fin |
copper
tubes&
hydrophilic aluminum fin(or
select copper fin) |
Drain inch |
3/8 |
3/8 |
3/8 |
1/2 |
3/4 |
3/4 |
1 |
1 |
1-1/2 |
1-1/2 |
2 |
2 |
2 |
reference Weights kg |
80 |
120 |
150 |
220 |
350 |
380 |
700 |
750 |
1150 |
1260 |
1880 |
2050 |
2870 |
Reference
dimensions |
H mm |
850 |
940 |
1150 |
1380 |
1760 |
1760 |
1250 |
1550 |
1750 |
1750 |
2200 |
2200 |
2200 |
W mm |
1050 |
1050 |
1050 |
1130 |
1260 |
1405 |
1650 |
1750 |
2000 |
2200 |
2000 |
2200 |
2200 |
D mm |
320 |
320 |
340 |
380 |
550 |
600 |
1000 |
1000 |
1100 |
1200 |
1500 |
1750 |
2000 |
consult pool water area m2 |
<15 |
<30 |
<50 |
40-80 |
70-120 |
100-150 |
130-250 |
170-300 |
250-500 |
350-600 |
450-800 |
700-1000 |
800-1200 |
|
Notice:- The capability condition:inlet
temperature is 30℃; relative humidity is 80%. In
different refrigeration or different operating
condition,the practical capacity will have
difference.
- dehumidify capacity not include fresh air
dehumidify.
- If need air auxiliary heating exchanger, air
changes fan,or other require(example auxiliary
electricity heating,air pressure,outside
dimension etc), please note when ordering.
- Suitable area for reference, the use of
results by the pool area, swimming pool space,
spatial structure, fresh air scale, people
amount etc.
- The company keeps the right of revising and
not informing customers. |
|
SWIMMING
POOL HEAT PUMP& DEHUMIDIFY & AIR-CONDITION
UNIT(RC-WA SERIES) |
FUNCTION: INDOOR AIR DEHUMIDIFY-
AIR HEATING – POOL WATER HEATING - FRESH AIR
SUPPLY(option)-AIR EXCHANGE(option) |
MODEL |
RC-2200WA |
RC-3750WA |
RC-6000WA |
RC-7500WA |
RC-11500WA |
RC-15000WA |
standard air flow m3/h |
2000 |
3000 |
4500 |
6000 |
9000 |
11000 |
dehumidify capacity L/h |
8 |
13 |
20 |
25 |
40 |
50 |
heat pump to air max heating capacityKw |
10.6 |
17.7 |
28 |
35.5 |
53.2 |
71 |
heat pump to water max heating
capacityKW |
10.6 |
17.7 |
28 |
35.5 |
53.2 |
71 |
refrigerant |
R-22(or
select R407c/R410A/R404A) |
around temperature |
5 - 40°C |
power source |
220/380 |
3Ø 380V 50HZ (or 60HZ) |
compressor total power Kw |
2.25 |
3.75 |
6 |
7.5 |
11.2 |
15 |
air fan |
amount |
1 |
1 |
1 |
1 |
1 |
1 |
excess pressurePa |
≥150 |
≥200 |
≥250 |
≥250 |
≥350 |
≥350 |
exchanger |
evaporator |
copper tubes&
hydrophilic aluminum fin(orselect copper
fin) |
condenser |
copper tubes&
aluminum fin |
Pool Water heater |
type |
titanium
pipe coil
&
PVC type |
pipe
dia mm |
DN20 |
DN25 |
DN40 |
DN40 |
DN50 |
DN50 |
option installation function |
air exchange fan |
Max air exchange amount standard air
flow(or according to request) |
air auxiliary heater |
air auxiliary heating or cooling
exchanger(flowing
hot water) |
Drain inch |
1/2 |
1/2 |
3/4 |
3/4 |
1 |
1 |
reference Weights kg |
160 |
240 |
380 |
475 |
610 |
820 |
Reference
dimensions |
H mm |
1460 |
1680 |
1760 |
1795 |
1950 |
1950 |
W mm |
820 |
910 |
1260 |
1405 |
1650 |
1650 |
D mm |
1100 |
1350 |
1500 |
1500 |
2000 |
2200 |
consult pool water area m2 |
<50 |
40-80 |
70-120 |
100-150 |
130-250 |
170-300 |
|
|
MODEL |
RC-22000WA |
RC-30000WA |
RC-37500WA |
RC-45000WA |
RC-60000WA |
standard air flow m3/h |
16000 |
22500 |
27500 |
32000 |
45000 |
dehumidify capacity L/h |
75 |
100 |
125 |
150 |
200 |
heat pump to air max heating capacity Kw |
106.5 |
142 |
177.5 |
213 |
284 |
heat pump to water max heating
capacityKw |
106.5 |
142 |
177.5 |
213 |
284 |
refrigerant |
R-22(or
select R407c/R410A/R404A) |
around temperature |
5 - 40°C |
power
source |
3Ø 380V 50HZ (or 60HZ) |
compressor total power Kw |
22.5 |
30 |
37.5 |
45 |
60 |
air fan |
amount |
1 |
1 |
1 |
1 |
1 |
excess pressure Pa |
≥450 |
≥450 |
≥450 |
≥450 |
≥450 |
exchanger |
evaporator |
copper
tubes&
hydrophilic aluminum fin(orselect copper
fin) |
condenser |
cross-finned tubes |
Pool Water heater |
type |
titanium
pipe coil
&
PVC or stainless steel plate type |
pipe
dia mm |
DN65 |
DN65 |
DN80 |
DN80 |
DN100 |
option installation function |
air exchange fan |
Max air exchange amount standard air
flow(or according to request) |
air auxiliary heater |
air auxiliary heating exchanger(flowing
hot water) |
Drain
inch |
1-1/2 |
1-1/2 |
1-1/2 |
2 |
2 |
reference Weights kg |
1320 |
1570 |
2050 |
2400 |
3200 |
Reference
dimensions |
H mm |
2000 |
2000 |
2200 |
2200 |
2200 |
W mm |
1850 |
2000 |
2000 |
2200 |
2200 |
D mm |
2500 |
3500 |
4000 |
4500 |
5000 |
consult pool water area m2 |
250-450 |
350-600 |
450-750 |
600-900 |
800-1200 |
|
Notice:- The capability condition:inlet
temperature is 30℃;
relative humidity is 80%. In different refrigeration or different operating
condition,the practical capacity will have
difference.
- dehumidify capacity not include fresh air
dehumidify.
- If need air auxiliary heating exchanger,air
exchange fan,or other require(example auxiliary
electricity heating,air pressure,outside
dimension etc), please note when ordering.
- Suitable area for reference, the use of
results by the pool area, swimming pool space,
spatial structure, fresh air scale, people
amount etc.
- The company keeps the right of revising and
not informing customers. |
|
SWIMMING POOL HEAT PUMP& DEHUMIDIFY &
AIR-CONDITION UNIT(RC-WTA / WC-WTA SERIES) |
FUNCTION: INDOOR AIR DEHUMIDIFY- AIR HEATING –
POOL WATER HEATING – AIR COOLING - FRESH AIR
SUPPLY-AIR EXCHANGE |
MODEL |
air cooled |
RC-2200WTA |
RC-3750WTA |
RC-6000WTA |
RC-7500WTA |
RC-11500WTA |
RC-15000WTA |
water cooled |
WC-2200WTA |
WC-3750WTA |
WC-6000WTA |
WC-7500WTA |
WC-11500WTA |
WC-15000WTA |
standard air flow m3/h |
2000 |
3000 |
4500 |
6000 |
9000 |
11000 |
dehumidify capacity L/h |
8 |
13 |
20 |
25 |
40 |
50 |
refrigerated
capacity Kw |
8.4 |
14 |
22 |
28 |
42 |
56 |
heat pump to air max heating capacity
Kw |
10.6 |
17.7 |
28 |
35.5 |
53.2 |
71 |
heat pump to water max heating
capacityKW |
10.6 |
17.7 |
28 |
35.5 |
53.2 |
71 |
refrigerant |
R-22(or select R407c/R410A/R404A) |
around temperature |
5 - 40°C |
power
source |
220/380 |
3Ø 380V 50HZ (or 60HZ) |
compressor total power Kw |
2.25 |
3.75 |
6 |
7.5 |
11.2 |
15 |
air fan |
amount |
2 |
2 |
2 |
2 |
2 |
2 |
excess pressure Pa |
≥150 |
≥200 |
≥250 |
≥250 |
≥350 |
≥350 |
air heater condenser |
copper tubes&
aluminum fin |
evaporator |
copper tubes& hydrophilic aluminum
fin(or select copper fin) |
air-cooled
split condenser |
type |
cross-finned tubes |
dim
H×W×D
mm |
600/600/500 |
750/850/600 |
750/850/600 |
750/850/600 |
750/850/600 |
950/1600/600 |
amount |
1 |
1 |
2 |
2 |
3 |
2 |
water-cooled condenser |
double-pipe
type or shell and tube type or
stainless steel plate type(inside
the unit) |
Pool Water heater |
type |
titanium
pipe coil
&
PVC or
shell and tube type |
pipe dia
mm |
DN20 |
DN25 |
DN40 |
DN40 |
DN50 |
DN50 |
option installation function |
air auxiliary heating or cooling
exchanger(flowing
hot water) |
Drain
inch |
1/2 |
1/2 |
3/4 |
3/4 |
1 |
1 |
reference Weights kg |
210 |
280 |
420 |
525 |
690 |
920 |
Reference
dimensions |
H mm |
1460 |
1680 |
1760 |
1795 |
1950 |
1950 |
W mm |
820 |
910 |
1260 |
1405 |
1650 |
1650 |
D mm |
1100-2000 |
1500-3500 |
consult
pool water area m2 |
<50 |
40-80 |
70-120 |
100-150 |
130-250 |
170-300 |
|
|
MODEL |
air cooled |
RC-22000WTA |
RC-30000WTA |
RC-37500WTA |
RC-45000WTA |
RC-60000WTA |
water cooled |
WC-22000WTA |
WC-30000WTA |
WC-37500WTA |
WC-45000WTA |
WC-60000WTA |
standard
air flow m3/h |
16000 |
22500 |
27500 |
32000 |
45000 |
dehumidify capacity L/h |
75 |
100 |
125 |
150 |
200 |
refrigerated
capacity Kw |
84 |
112 |
140 |
168 |
224 |
heat pump to air max heating capacityKw |
106.5 |
142 |
177.5 |
213 |
284 |
heat pump to water max heating
capacityKw |
106.5 |
142 |
177.5 |
213 |
284 |
refrigerant |
R-22(or
select R407c/R410A/R404A) |
around temperature |
5 - 40°C |
power
source |
3Ø 380V 50HZ (or 60HZ) |
compressor total power Kw |
22.5 |
30 |
37.5 |
45 |
60 |
air
fan |
amount |
2 |
2 |
2 |
2 |
2 |
excess pressurePa |
≥450 |
≥450 |
≥450 |
≥450 |
≥450 |
air heater condenser |
copper
tubes&
aluminum fin |
evaporator |
copper
tubes&
hydrophilic aluminum fin |
air-cooled
split condenser |
type |
cross-finned tubes |
dim
H×W×D
mm |
950/1600/600 |
950/1600/600 |
1150/1600/600 |
1250/1600/1350 |
1250/1600/1350 |
amount |
3 |
4 |
4 |
3 |
4 |
water-cooled condenser |
double-pipe type or shell and tube type
or
stainless steel plate type(inside
the unit) |
Pool Water heater |
type |
titanium
pipe coil
&
PVC or
shell and tube type |
pipe
dia mm |
DN65 |
DN65 |
DN80 |
DN80 |
DN100 |
option installation function |
air auxiliary heating exchanger(flowing
hot water) |
protection device |
Voltage protector,anti-phase &
lack-phase protector,time delay,the
control and display of high and low
pressure,temperature protector,the
control and display of temperature,the
protectionof over load,the oil
heating,the errors display and so on. |
Drain
inch |
1-1/2 |
1-1/2 |
1-1/2 |
2 |
2 |
reference Weights kg |
1320 |
1570 |
2050 |
2400 |
3200 |
Reference
dimensions |
H mm |
2000 |
2000 |
2200 |
2200 |
2200 |
W mm |
1850 |
2000 |
2000 |
2200 |
2200 |
D mm |
2500-5000 |
4500-6000 |
consult pool water area m2 |
250-450 |
350-600 |
450-750 |
600-900 |
800-1200 |
|
Notice:- The capability
condition:inlet temperature is 30℃; relative
humidity is 80%. In different refrigeration or
different operating condition,the practical
capacity will have difference.
- dehumidify capacity not include
fresh air dehumidify.
- If need air auxiliary heating
exchanger,air exchange fan,or other
require(example auxiliary electricity
heating,air pressure,outside dimension etc),
please note when ordering.
- Suitable area for reference,
the use of results by the pool area, swimming
pool space, spatial structure, fresh air scale,
people amount etc.
- The company keeps the right of
revising and not informing customers. |
|
|
|
|